-- *****************************************************************************
-- Juniper-UNI-SONET-MIB
--
-- Juniper Networks Enterprise MIB
-- SONET MIB
--
-- Copyright (c) 1998 Redstone Communications, Inc.
-- Copyright (c) 1999, 2001 Unisphere Networks, Inc.
-- Copyright (c) 2002, 2003 Juniper Networks, Inc.
-- All Rights Reserved.
-- *****************************************************************************Juniper-UNI-SONET-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,Unsigned32,Integer32,NOTIFICATION-TYPEFROM SNMPv2-SMI
DisplayString,TruthValue,TEXTUAL-CONVENTION,RowStatusFROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUP,NOTIFICATION-GROUPFROM SNMPv2-CONF
ifIndex,InterfaceIndex,InterfaceIndexOrZero, ifAlias
FROM IF-MIB
JuniNextIfIndex
FROM Juniper-TC
juniMibs
FROM Juniper-MIBs;juniSonetMIB MODULE-IDENTITYLAST-UPDATED"200307161952Z"-- 16-Jul-03 03:52 PM EDTORGANIZATION"Juniper Networks, Inc."CONTACT-INFO" Juniper Networks, Inc.
Postal: 10 Technology Park Drive
Westford, MA 01886-3146
USA
Tel: +1 978 589 5800
Email: mib@Juniper.net"DESCRIPTION"The SONET MIB for the Juniper Networks enterprise. This MIB contains
managed objects for SONET interfaces. It contains management objects
for configuration of interface attributes that either are absent from,
or read-only in the standard SONET-MIB."-- Revision HistoryREVISION"200307161952Z"-- 16-Jul-03 03:52 PM EDT - JUNOSe 5.1DESCRIPTION"Added path event status and notification support.
Updated path creation description.
Added missing default values."REVISION"200211221637Z"-- 22-Nov-02 11:37 AM EST - JUNOSe 5.0DESCRIPTION"Replaced Unisphere names with Juniper names.
Expanded MIB to include following objects:
juniSonetMediumTriggerAlarms
juniSonetMediumTriggerDelay
juniSonetPathTriggerAlarms
juniSonetPathTriggerDelay
juniSonetPathC2ByteOverrideFlag
juniSonetPathC2ByteOverride "
REVISION"200110102042Z"-- 10-Oct-01 04:42 PM EDT - JUNOSe 3.2DESCRIPTION"Deprecated juniSonetMediumType, juniSonetMediumCircuitIdentifier and
juniSonetVTType."REVISION"200101021800Z"-- 02-Jan-01 01:00 PM EST - JUNOSe 3.0DESCRIPTION"Expanded MIB to include following tables and objects:
juniSonetPathCapabilityTable
juniSonetPathNextIfIndex
juniSonetPathTable
juniSonetVTNextIfIndex
juniSonetVTTable "REVISION"9811130000Z"-- 13-Nov-98 - JUNOSe 1.0DESCRIPTION"Initial version of this MIB module."::={ juniMibs 7}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++JuniSonetLineSpeed ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The set of SONET Line Speeds."SYNTAXINTEGER{sonetUnknownSpeed(0),sonetOc1Stm0(1),sonetOc3Stm1(2),
sonetOc12Stm3(3),sonetOc48Stm16(4)}JuniSonetLogicalPathChannel ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"A SONET Path channel description that uniquely identifies the SONET
Path and is administratively assigned."SYNTAXInteger32(0..2147483647)JuniSonetPathHierarchy ::=TEXTUAL-CONVENTIONDISPLAY-HINT"32a"STATUScurrentDESCRIPTION"Represents textual information taken from the NVT ASCII character set.
The SONET path hierarchy is based upon the SONET line capacity.
Configuration examples follow the diagram below, which depicts the SONET
Path hierarchy.
OC-192/STM-64
^
|
OC-48/STM-16 (1-4)
^
|
OC-12/STM-4 (1-4)
^
|
OC-3/STM-1 (1-4)
^
|
OC-1/STM-0 (1-3)
^
|
^----------------^----------------^
| | |
DS3 (1) VT1.5/TU11 DS1 (1-28) VT2/TU12 (1-21)
For Line Speed = OC-48/STM-16:
When the entire capacity contains only one path, no specifier
is used.
OC-12/STM-4 Path
To specify an OC-12 path over OC-48 provide a single digit of
the form a where:
a - OC-12/STM-4 path number (1-4)
OC-3/STM-1 Path
To specify an OC-3 Path over OC-48 provide two digits of the
form a/b where:
a - OC-12/STM-4 path number (1-4)
b - OC-3/STM-1 path within the OC-12 (1-4)
OC-1/STM-0 Path
To specify an OC1 Path over OC-48 provide three digits of the
form a/b/c where:
a - OC-12/STM-4 path number (1-4)
b - OC-3/STM-1 path number within OC-12 (1-4)
c - OC-1/STM-0 path number within OC-3 (1-3)
For Line Speed = OC-12/STM-4:
OC-12/STM-4 Path:
When entire line capacity contains only one path, no
channel-specifier is used.
OC-3/STM-1 Path:
To specify an OC-3 path over OC-12 provide a single digit of
the form a where:
a - OC-3/STM-1 path within the OC-12 (1-4)
OC-1 Path:
To specify an OC-1 path over OC-12 provide two digits of the
form a/b where:
a - OC-3/STM-1 path within the OC-12 (1-4)
b - OC-1/STM-0 path within the OC-3 (1-3)
For Line Speed = OC-3/STM-1:
OC-3/STM-1 Path:
When entire line capacity contains only one path, no
channel-specifier is used.
OC-1 Path:
To specify an OC-1 path over OC-3 provide one digit of the
form a where:
a - OC-1/STM-1 path within the OC-3 (1-3) "REFERENCE"RFC 854: NVT ASCII character set. See SNMPv2-TC.DisplayString
DESCRIPTION for a summary."SYNTAXOCTETSTRING(SIZE(0..32))JuniSonetPathC2ByteOverride ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"SONET Path c2 overhead byte.
This value should only be set in cases where the value set by
the upper interface type needs to be overridden. Standard values
are:
0 Unequipped
1 Nonspecific
2 Floating VT
4 Asyncronous mapping of DS3
19 ATM
22 HDLC over Sonet - scrambling enabled
207 HDLC over Sonet - no scrambling"SYNTAXInteger32(0..255)JuniSonetVTType ::=TEXTUAL-CONVENTIONSTATUSdeprecatedDESCRIPTION"The SONET Virtual Tributary Type. This TC has been deprecated because
RFC2558 provides this information in SONET-MIB.sonetVTCurrentWidth."SYNTAXINTEGER{
tribVT15TU11(0),tribVT20TU12(1),tribVT3(3),tribVT6(4),tribVT6c(5)}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++juniSonetObjects OBJECTIDENTIFIER::={ juniSonetMIB 1}juniSonetPathObjects OBJECTIDENTIFIER::={ juniSonetMIB 2}juniSonetVTObjects OBJECTIDENTIFIER::={ juniSonetMIB 3}-- /////////////////////////////////////////////////////////////////////////////
--
-- SONET Interfaces
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- The SONET Interface Table
--juniSonetMediumTable OBJECT-TYPESYNTAXSEQUENCEOF JuniSonetMediumEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"This table contains entries for SONET interfaces present in the
system."::={ juniSonetObjects 1}juniSonetMediumEntry OBJECT-TYPESYNTAX JuniSonetMediumEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an SONET interface."INDEX{ ifIndex }::={ juniSonetMediumTable 1}
JuniSonetMediumEntry ::=SEQUENCE{
juniSonetMediumType INTEGER,
juniSonetMediumLoopbackConfig INTEGER,
juniSonetMediumTimingSource INTEGER,
juniSonetMediumCircuitIdentifier DisplayString,
juniSonetMediumTriggerAlarms BITS,
juniSonetMediumTriggerDelay Integer32}juniSonetMediumType OBJECT-TYPESYNTAXINTEGER{sonet(1),sdh(2)}
MAX-ACCESSread-writeSTATUSdeprecatedDESCRIPTION"This variable identifies whether a SONET or a SDH signal is used across
this interface. This object was deprecated because the same information
is provided by the SONET-MIB.sonetMediumType object (RFC 2558)."::={ juniSonetMediumEntry 1}juniSonetMediumLoopbackConfig OBJECT-TYPESYNTAXINTEGER{sonetNoLoop(0),sonetFacilityLoop(1),sonetTerminalLoop(2),sonetOtherLoop(3)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The current loopback state of the SONET/SDH interface.
The values mean:
sonetNoLoop Not in the loopback state. A device that is not
capable of performing a loopback on this
interface shall always return this value.
sonetFacilityLoop The received signal at this interface is looped
back out through the corresponding transmitter in
the return direction.
sonetTerminalLoop The signal that is about to be transmitted is
connected to the associated incoming receiver.
sonetOtherLoop Loopbacks that are not defined here."::={ juniSonetMediumEntry 2}juniSonetMediumTimingSource OBJECT-TYPESYNTAXINTEGER{loop(0),internalModule(1),internalChassis(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Selects the source from which transmit timing is derived.
loop timing is recovered from the receiver
internalModule timing is from the module associated with this
interface
internalChassis timing is taken from the internal system timing
reference "::={ juniSonetMediumEntry 3}juniSonetMediumCircuitIdentifier OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-writeSTATUSdeprecated
DESCRIPTION"This variable contains the transmission vendor's circuit identifier,
for the purpose of facilitating troubleshooting. This object was
deprecated because the same information is provided by the
SONET-MIB.sonetMediumCircuitIdentifier object (RFC 2558)."::={ juniSonetMediumEntry 4}juniSonetMediumTriggerAlarms OBJECT-TYPESYNTAXBITS{sectionLOS(0),sectionLOF(1),lineAIS(2),lineRDI(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The alarms that are used in the operational status calculation for this
SONET interface.
sectionLOS When this bit is set, section LOS is used for
operational status calculation.
sectionLOF When this bit is set, section LOF is used for
operational status calculation.
lineAIS When this bit is set, line AIS is used for operational
status calculation.
lineRDI When this bit is set, line RDI is used for operational
status calculation.
The value of this object defaults to all the bits set, indicating all of
the alarms are used for the operational status calculation."DEFVAL{{ sectionLOS, sectionLOS, lineAIS, lineRDI }}::={ juniSonetMediumEntry 5}juniSonetMediumTriggerDelay OBJECT-TYPESYNTAXInteger32(0..2500)UNITS"ms"MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The time delay (in milliseconds) before a defect is accepted as an
alarm for this SONET interface."DEFVAL{2500}::={ juniSonetMediumEntry 6}--
-- The SONET Path Capabilities Table
--juniSonetPathCapabilityTable OBJECT-TYPESYNTAXSEQUENCEOF JuniSonetPathCapabilityEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for SONET Paths present in the system."::={ juniSonetPathObjects 1}
juniSonetPathCapabilityEntry OBJECT-TYPESYNTAX JuniSonetPathCapabilityEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the SONET path capability of a SONET interface.
This table is index by the ifIndex of the SONET interface."INDEX{ ifIndex }::={ juniSonetPathCapabilityTable 1}
JuniSonetPathCapabilityEntry ::=SEQUENCE{
juniSonetPathRemoveFlag TruthValue,
juniSonetPathChannelized TruthValue,
juniSonetPathMaximumChannels Unsigned32,
juniSonetPathMinimumPathSpeed JuniSonetLineSpeed,
juniSonetPathMaximumPathSpeed JuniSonetLineSpeed }juniSonetPathRemoveFlag OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable identifies whether a SONET/SDH supports the deletion of
SONET Paths. A value of true(1) indicates the SONET path is removable;
a value of false(2) indicates the SONET path cannot be removed."::={ juniSonetPathCapabilityEntry 1}
juniSonetPathChannelized OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Identifies whether or not this SONET interface supports channelization.
A value of true(1) indicates the SONET path is channelized; a value of
false(2) indicates the SONET path is not channelized."::={ juniSonetPathCapabilityEntry 2}juniSonetPathMaximumChannels OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Identifies the maximum number of SONET paths/channels for this
interface."::={ juniSonetPathCapabilityEntry 3}juniSonetPathMinimumPathSpeed OBJECT-TYPESYNTAX JuniSonetLineSpeed
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Identifies the minimum SONET path speed for this interface."::={ juniSonetPathCapabilityEntry 4}juniSonetPathMaximumPathSpeed OBJECT-TYPE
SYNTAX JuniSonetLineSpeed
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Identifies the maximum SONET path speed for this interface."::={ juniSonetPathCapabilityEntry 5}--
-- The SONET Path Interface Objects
--juniSonetPathNextIfIndex OBJECT-TYPESYNTAX JuniNextIfIndex
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Coordinate ifIndex value allocation for entries in juniSonetPathTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."::={ juniSonetPathObjects 2}--
-- The SONET Path Interface Table
--juniSonetPathTable OBJECT-TYPESYNTAXSEQUENCEOF JuniSonetPathEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"This table contains entries for SONET Path interfaces present in the
system."::={ juniSonetPathObjects 3}juniSonetPathEntry OBJECT-TYPESYNTAX JuniSonetPathEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an SONET Path interface."INDEX{ juniSonetPathIfIndex }::={ juniSonetPathTable 1}
JuniSonetPathEntry ::=SEQUENCE{
juniSonetPathIfIndex InterfaceIndex,
juniSonetPathLogicalChannel JuniSonetLogicalPathChannel,
juniSonetPathSpeed JuniSonetLineSpeed,
juniSonetPathHierarchy JuniSonetPathHierarchy,
juniSonetPathLowerIfIndex InterfaceIndexOrZero,
juniSonetPathRowStatus RowStatus,
juniSonetPathTriggerAlarms BITS,
juniSonetPathC2ByteOverrideFlag TruthValue,
juniSonetPathC2ByteOverride JuniSonetPathC2ByteOverride,
juniSonetPathTriggerDelay Integer32,
juniSonetPathEventStatus Unsigned32}juniSonetPathIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the SONET Path interface. When creating entries in this
table, suitable values for this object are determined by reading
juniSonetPathNextIfIndex."::={ juniSonetPathEntry 1}juniSonetPathLogicalChannel OBJECT-TYPESYNTAX JuniSonetLogicalPathChannel
MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The logical channel number assigned to this SONET Path. If the
underlying SONET interface does not support channelization, the value of
this object is zero."::={ juniSonetPathEntry 2}juniSonetPathSpeed OBJECT-TYPESYNTAX JuniSonetLineSpeed
MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The line speed associated with this SONET PATH."::={ juniSonetPathEntry 3}
juniSonetPathHierarchy OBJECT-TYPESYNTAX JuniSonetPathHierarchy
MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The SONET Path hierarchy associated with this path."::={ juniSonetPathEntry 4}juniSonetPathLowerIfIndex OBJECT-TYPESYNTAXInterfaceIndexOrZeroMAX-ACCESSread-createSTATUScurrentDESCRIPTION"The ifIndex of the interface over which this SONET Path interface is to
be layered - typically a SONET/SDH interface. A value of zero indicates
no layering. An implementation may choose to require that a nonzero
value be configured at entry creation."::={ juniSonetPathEntry 5}juniSonetPathRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniSonetPathRowStatus
juniSonetPathSpeed
juniSonetPathHierarchy
juniSonetPathLowerIfIndex
The logical channel may optionally be specified. If it is not specified
an unused logical channel value will be assigned by the system.
juniSonetPathLogicalChannel
In addition, when creating an entry the following conditions must hold:
A value for juniSonetPathIfIndex must have been determined
previously, by reading juniSonetPathNextIfIndex.
The interface identified by the juniSonetPathLowerIfIndex must
exist.
The juniSonetPathSpeed must be consistent with the speed for the
channel specified by the juniSonetPathHierarchy, based on the speed
of the interface identified by the juniSonetPathLowerIfIndex.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table."::={ juniSonetPathEntry 6}juniSonetPathTriggerAlarms OBJECT-TYPESYNTAXBITS{pathLOP(0),pathAIS(1),pathRDI(2)}MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The path alarms that are used in the operational status calculation for
this SONET Path.
pathLOP When this bit is set, path LOP is used for operational
status calculation. This bit may not be modified.
pathAIS When this bit is set, path AIS is used for operational
status calculation. This bit may not be modified.
pathRDI When this bit is set, path RDI is used for operational
status calculation.
The value of this object defaults to bits 0 and 1 set, indication LOP
and AIS will be used for operational status calculation this SONET
Path."DEFVAL{{ pathLOP, pathAIS }}::={ juniSonetPathEntry 7}juniSonetPathC2ByteOverrideFlag OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-createSTATUScurrentDESCRIPTION"The path overhead c2 transmit override enable. If set to true(1),
juniSonetPathC2Byte override value must be specified. If set to
false(2), c2 byte will be automatically set by the system based on the
upper interface type."DEFVAL{ false }::={ juniSonetPathEntry 8}juniSonetPathC2ByteOverride OBJECT-TYPESYNTAX JuniSonetPathC2ByteOverride
MAX-ACCESSread-create
STATUScurrentDESCRIPTION"The path overhead c2 transmit and expected value for this SONET Path."DEFVAL{0}::={ juniSonetPathEntry 9}juniSonetPathTriggerDelay OBJECT-TYPESYNTAXInteger32(0..2500)UNITS"ms"MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The time delay (in milliseconds) before a defect is accepted as an
alarm for this SONET Path."DEFVAL{2500}::={ juniSonetPathEntry 10}juniSonetPathEventStatus OBJECT-TYPESYNTAXUnsigned32(0..32767)MAX-ACCESSaccessible-for-notifySTATUScurrentDESCRIPTION"This variable specifies which events have occurred in the current 15
minute interval. The value represents a vector of bits, each specifying
a unique event:
- Bit 0 Rising threshold alarm, sonetPathCurrentESs.
- Bit 1 Rising threshold alarm, sonetPathCurrentSESs.
- Bit 2 Reserved.
- Bit 3 Rising threshold alarm, sonetPathCurrentCVs.
- Bit 4 Rising threshold alarm, sonetPathCurrentUASs.
- Bit 5 LOP failure indication.
- Bit 6 LOP failure cleared.
- Bit 7 AIS failure indication.
- Bit 8 AIS failure cleared.
- Bit 9 RFI indication.
- Bit 10 RFI cleared.
- Bit 11 UNEQ failure indication.
- Bit 12 UNEQ failure cleared.
- Bit 13 PLM failure indication.
- Bit 14 PLM failure cleared. "::={ juniSonetPathEntry 11}--
-- The SONET Virtual Tributary Interface Objects
--juniSonetVTNextIfIndex OBJECT-TYPESYNTAX JuniNextIfIndex
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Coordinate ifIndex value allocation for entries in juniSonetVTTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."::={ juniSonetVTObjects 1}
--
-- The SONET Virtual Tributary Interface Table
--juniSonetVTTable OBJECT-TYPESYNTAXSEQUENCEOF JuniSonetVTEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for SONET Virtual Tributary interfaces
present in the system. This table augments the standard
SONET-MIB.sonetVTCurrentTable."::={ juniSonetVTObjects 2}juniSonetVTEntry OBJECT-TYPESYNTAX JuniSonetVTEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an SONET Virtual Tributary
interface."INDEX{ juniSonetVTIfIndex }::={ juniSonetVTTable 1}
JuniSonetVTEntry ::=SEQUENCE{
juniSonetVTIfIndex InterfaceIndex,
juniSonetVTPathLogicalChannel JuniSonetLogicalPathChannel,
juniSonetVTType JuniSonetVTType,
juniSonetVTPathPayload Unsigned32,
juniSonetVTTributaryGroup Unsigned32,
juniSonetVTTributarySubChannel Unsigned32,
juniSonetVTLowerIfIndex InterfaceIndexOrZero,
juniSonetVTRowStatus RowStatus}juniSonetVTIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the SONET Virtual Tributary interface. When creating
entries in this table, suitable values for this object are determined by
reading juniSonetVTNextIfIndex."::={ juniSonetVTEntry 1}juniSonetVTPathLogicalChannel OBJECT-TYPESYNTAX JuniSonetLogicalPathChannel
MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The SONET Path logical channel number associated with this virtual
tributary."::={ juniSonetVTEntry 2}juniSonetVTType OBJECT-TYPESYNTAX JuniSonetVTType
MAX-ACCESSread-createSTATUSdeprecatedDESCRIPTION"The SONET virtual tributary type. This object was deprecated because
the same information is provided in the SONET-MIB.sonetVTCurrentWidth
object."::={ juniSonetVTEntry 3}juniSonetVTPathPayload OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The SONET Path payload number associated with this virtual tributary.
For SDH mode, this is a value with a range from 1-3. For SONET mode,
the value of this object is always 1."::={ juniSonetVTEntry 4}juniSonetVTTributaryGroup OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The SONET Path group number for this virtual tributary. In SONET and
SDH mode, the value of this object is 1-7."::={ juniSonetVTEntry 5}juniSonetVTTributarySubChannel OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-createSTATUScurrentDESCRIPTION"Specifies the virtual tributary number within the tributary group
defined by juniSonetVTTributaryGroup object. The value of this object
ranges from 1-4 if the tributary type is tribVT15/TU11(0); and the
values 1-3 if the tributary type is tribVT20/TU12(1)."::={ juniSonetVTEntry 6}juniSonetVTLowerIfIndex OBJECT-TYPESYNTAXInterfaceIndexOrZeroMAX-ACCESSread-createSTATUScurrentDESCRIPTION"The ifIndex of the interface over which this SONET Virtual Tributary
interface is to be layered - typically a SONET PATH interface.
A value of zero indicates no layering. An implementation may choose to
require that a nonzero value be configured at entry creation."::={ juniSonetVTEntry 7}juniSonetVTRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniSonetVTRowStatus
juniSonetVTPathLogicalChannel
juniSonetVTType
juniSonetVTPathPayload
juniSonetVTTributaryGroup
juniSonetVTTributarySubChannel
juniSonetVTLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniSonetVTIfIndex must have been determined previously,
by reading juniSonetVTNextIfIndex.
The interface identified by juniSonetVTLowerIfIndex must exist.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table."::={ juniSonetVTEntry 8}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notification control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++juniSonetTrapControl OBJECTIDENTIFIER::={ juniSonetMIB 5}juniSonetPathEventIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSaccessible-for-notifySTATUScurrentDESCRIPTION"The ifIndex of the SONET Path interface. This is the same value as
juniSonetPathIfIndex for the interface that is reporting an event."::={ juniSonetTrapControl 1}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- The following two OBJECT IDENTIFIERS are used to define SNMPv2 notifications
-- that are easily translated into SNMPv1 Traps.juniSonetTraps OBJECTIDENTIFIER::={ juniSonetMIB 6}juniSonetTrapPrefix OBJECTIDENTIFIER::={ juniSonetTraps 0}juniSonetPathEvents NOTIFICATION-TYPEOBJECTS{
juniSonetPathEventIfIndex,
juniSonetPathEventStatus,
ifAlias }STATUScurrentDESCRIPTION"This trap reports SONET path events for the failures and normal
conditions of the SONET path entity."::={ juniSonetTrapPrefix 1}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++juniSonetConformance OBJECTIDENTIFIER::={ juniSonetMIB 4}juniSonetCompliances OBJECTIDENTIFIER::={ juniSonetConformance 1}juniSonetGroups OBJECTIDENTIFIER::={ juniSonetConformance 2}
--
-- compliance statements
--juniSonetCompliance MODULE-COMPLIANCESTATUSobsoleteDESCRIPTION"Obsolete compliance statement for entities which implement the Juniper
SONET MIB. This statement became obsolete when the SONET Path and SONET
VT groups of objects were added."MODULE-- this moduleMANDATORY-GROUPS{
juniSonetGroup }::={ juniSonetCompliances 1}-- JUNOSe 1.0juniSonetCompliance2 MODULE-COMPLIANCESTATUSobsoleteDESCRIPTION"Obsolete compliance statement for entities which implement the Juniper
SONET MIB. This statement became obsolete when the juniSonetMediumType,
juniSonetMediumCircuitIdentifier and juniSonetVTType objects were
deprecated."MODULE-- this moduleMANDATORY-GROUPS{
juniSonetGroup,
juniSonetPathGroup }GROUP juniSonetVirtualTributaryGroup
DESCRIPTION"This group is mandatory only for those entities that support
SONET virtual tributaries."::={ juniSonetCompliances 2}-- JUNOSe 3.0
juniSonetCompliance3 MODULE-COMPLIANCESTATUSobsoleteDESCRIPTION"Obsolete compliance statement for entities which implement the Juniper
SONET MIB. This statement became obsolete when support was added for
alarm triggers and path c2 byte override."MODULE-- this moduleMANDATORY-GROUPS{
juniSonetGroup2,
juniSonetPathGroup }GROUP juniSonetVirtualTributaryGroup2
DESCRIPTION"This group is mandatory only for those entities that support
SONET virtual tributaries."::={ juniSonetCompliances 3}-- JUNOSe 3.2juniSonetCompliance4 MODULE-COMPLIANCESTATUSobsoleteDESCRIPTION"Obsolete compliance statement for entities which implement the Juniper
SONET MIB. This statement became obsolete when the SONET Path event
status and notification support was added."MODULE-- this moduleMANDATORY-GROUPS{
juniSonetGroup3,
juniSonetPathGroup2 }GROUP juniSonetVirtualTributaryGroup2
DESCRIPTION"This group is mandatory only for those entities that support
SONET virtual tributaries."::={ juniSonetCompliances 4}-- JUNOSe 5.0juniSonetCompliance5 MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities which implement the Juniper SONET
MIB."MODULE-- this moduleMANDATORY-GROUPS{
juniSonetGroup3,
juniSonetPathGroup3,
juniSonetPathNotificationGroup }GROUP juniSonetVirtualTributaryGroup2
DESCRIPTION"This group is mandatory only for those entities that support
SONET virtual tributaries."::={ juniSonetCompliances 5}-- JUNOSe 5.1--
-- units of conformance
--juniSonetGroup OBJECT-GROUPOBJECTS{
juniSonetMediumType,
juniSonetMediumLoopbackConfig,
juniSonetMediumTimingSource,
juniSonetMediumCircuitIdentifier }STATUSobsolete
DESCRIPTION"Obsolete collection of objects providing management of SONET/SDH
interfaces in a Juniper product. This group became obsolete when the
juniSonetMediumType and juniSonetMediumCircuitIdentifier objects were
deprecated."::={ juniSonetGroups 1}-- JUNOSe 1.0juniSonetPathGroup OBJECT-GROUPOBJECTS{
juniSonetPathRemoveFlag,
juniSonetPathChannelized,
juniSonetPathMaximumChannels,
juniSonetPathMinimumPathSpeed,
juniSonetPathMaximumPathSpeed,
juniSonetPathNextIfIndex,
juniSonetPathLogicalChannel,
juniSonetPathSpeed,
juniSonetPathHierarchy,
juniSonetPathLowerIfIndex,
juniSonetPathRowStatus }STATUSobsoleteDESCRIPTION"Obsolete collection of objects providing management of SONET/SDH Path
interfaces in a Juniper product. This group became obsolete when new
SONET path objects were added."::={ juniSonetGroups 2}-- JUNOSe 3.0juniSonetVirtualTributaryGroup OBJECT-GROUPOBJECTS{
juniSonetVTNextIfIndex,
juniSonetVTPathLogicalChannel,
juniSonetVTType,
juniSonetVTPathPayload,
juniSonetVTTributaryGroup,
juniSonetVTTributarySubChannel,
juniSonetVTLowerIfIndex,
juniSonetVTRowStatus }STATUSobsoleteDESCRIPTION"Obsolete collection of objects providing management of SONET virtual
tributaries in a Juniper product. This group became obsolete when
juniSonetVTType was deprecated."::={ juniSonetGroups 3}-- JUNOSe 3.0juniSonetGroup2 OBJECT-GROUPOBJECTS{
juniSonetMediumLoopbackConfig,
juniSonetMediumTimingSource }STATUSobsoleteDESCRIPTION"Obsolete collection of objects providing management of SONET/SDH
interfaces in a Juniper product. This group became obsolete when
juniSonetMediumTriggerAlarms was added."::={ juniSonetGroups 4}-- JUNOSe 3.2juniSonetVirtualTributaryGroup2 OBJECT-GROUPOBJECTS{
juniSonetVTNextIfIndex,
juniSonetVTPathLogicalChannel,
juniSonetVTPathPayload,
juniSonetVTTributaryGroup,
juniSonetVTTributarySubChannel,
juniSonetVTLowerIfIndex,
juniSonetVTRowStatus }STATUScurrentDESCRIPTION"A collection of objects providing management of SONET virtual
tributaries in a Juniper product."::={ juniSonetGroups 5}-- JUNOSe 3.2juniSonetDeprecatedMediumGroup OBJECT-GROUPOBJECTS{
juniSonetMediumType,
juniSonetMediumCircuitIdentifier }STATUSdeprecatedDESCRIPTION"A collection of deprecated objects providing management of SONET/SDH
interfaces in a Juniper product. This group is deprecated because the
same information is provided by SONET-MIB objects (RFC 2558). Support
for the objects in this group will be phased out over time."::={ juniSonetGroups 6}-- JUNOSe 3.2juniSonetDeprecatedVTGroup OBJECT-GROUPOBJECTS{
juniSonetVTType }STATUSdeprecatedDESCRIPTION"A deprecated object providing management of SONET/SDH VT interfaces in
a Juniper product. This group is deprecated because the same
information is provided by SONET-MIB objects (RFC 2558). Support for
the VT type object will be phased out over time."::={ juniSonetGroups 7}-- JUNOSe 3.2juniSonetGroup3 OBJECT-GROUPOBJECTS{
juniSonetMediumLoopbackConfig,
juniSonetMediumTimingSource,
juniSonetMediumTriggerAlarms,
juniSonetMediumTriggerDelay }STATUScurrentDESCRIPTION"A collection of objects providing management of SONET/SDH interfaces in
a Juniper product."::={ juniSonetGroups 8}-- JUNOSe 5.0juniSonetPathGroup2 OBJECT-GROUPOBJECTS{
juniSonetPathRemoveFlag,
juniSonetPathChannelized,
juniSonetPathMaximumChannels,
juniSonetPathMinimumPathSpeed,
juniSonetPathMaximumPathSpeed,
juniSonetPathNextIfIndex,
juniSonetPathLogicalChannel,
juniSonetPathSpeed,
juniSonetPathHierarchy,
juniSonetPathLowerIfIndex,
juniSonetPathRowStatus,
juniSonetPathTriggerAlarms,
juniSonetPathC2ByteOverrideFlag,
juniSonetPathC2ByteOverride,
juniSonetPathTriggerDelay }STATUSobsoleteDESCRIPTION"Obsolete collection of management objects providing management of
SONET/SDH Path interfaces in a Juniper product. This group became
obsolete when path event notification support was added."::={ juniSonetGroups 9}-- JUNOSe 5.0juniSonetPathGroup3 OBJECT-GROUPOBJECTS{
juniSonetPathRemoveFlag,
juniSonetPathChannelized,
juniSonetPathMaximumChannels,
juniSonetPathMinimumPathSpeed,
juniSonetPathMaximumPathSpeed,
juniSonetPathNextIfIndex,
juniSonetPathLogicalChannel,
juniSonetPathSpeed,
juniSonetPathHierarchy,
juniSonetPathLowerIfIndex,
juniSonetPathRowStatus,
juniSonetPathTriggerAlarms,
juniSonetPathC2ByteOverrideFlag,
juniSonetPathC2ByteOverride,
juniSonetPathTriggerDelay,
juniSonetPathEventIfIndex,
juniSonetPathEventStatus }
STATUScurrentDESCRIPTION"A collection of objects providing management of SONET/SDH Path
interfaces in a Juniper product."::={ juniSonetGroups 10}-- JUNOSe 5.1juniSonetPathNotificationGroup NOTIFICATION-GROUPNOTIFICATIONS{
juniSonetPathEvents }STATUScurrentDESCRIPTION"A management notification for signaling SONET Path interface status
changes in a Juniper product."::={ juniSonetGroups 11}-- JUNOSe 5.1END